FAQ

risoluzioni problemiThe safety light curtain is not working properly:

The instructions given by the LEDs on the projector on the receiver and on the control unit allows in most cases to identify the cause of an incorrect operation of the system.

EOS4 Family safety light curtains

  • EOS4 Safety light curtains -  LED Meaning  (Ita, Eng, Fra, Spa, Ted)

ADMIRAL Family safety light curtains

  • ADMIRAL Safety light curtains - LED Meaning (Ita, Eng)
  • ADMIRAL AX Safety light curtains - LED Meaning (Ita, Eng)
  • ADMIRAL AX BK Safety light curtains LED Meaning (Ita, Eng)

JANUS Family safety light curtains

  • JANUS Safety light curtains LED Meaning (Ita, Eng)
  • JANUS TRX Safety light curtains LED Meaning (Ita, Eng) 

EOS2 Family safety light curtains

  • EOS2 Safety light curtains LED Menaing (Ita, Eng, Fra, Spa, Ted)

VISION Family safety light curtains

  • VISION Safety light curtains LED Meaning (Ita, Eng)
  • VISION VX Safety light curtains LED Meaning (Ita, Eng).

 

The meaning of the LEDs does not allow to identify the fault:

In any case we recommend a system crash, sending the test command to verify that the cause of the abnormal behavior is not attributable to any electromagnetic interference of random character.

In the case of operating irregularities that there even after sending the test command and, later, after shutting down and restarting the system:

  • check the integrity and fairness of the electrical connections;-check that the power supply voltage levels conform to those indicated in the technical data;
  • check that any relay or external contactors are used correctly and with adequate suppression modules indicated by the manufacturer;
  • check that the projector and receiver are correctly aligned and that the optics are clean;
  • check the working distance (vapors or fumes may cause occasional occupations for use at maximum flow rate);
  • check that the barrier is not subjected to vibrations (momentary loss of alignment);
  • check that there are no two or more users who work near or alongside and a receiver cannot "see other projectors" in addition to its own;
  • check that the barrier is not placed near reflective surfaces (e.g. transparencies or sheet metal panels);
  • Verify that all elements of the system have a good grounding;

If the suggested controls are not sufficient to restore the proper functioning of the system, send the appliance to our laboratories, complete with all its parts, indicating with clarity:

  • serial number;-date of purchase;
  • period of operation;
  • type of installation;
  • fault detected.
The MOSAIC Controller is not working properly:

The instructions given by the LEDs on the Mosiac modules allows in most cases to identify the cause of an incorrect operation of the system.

  • Mosaic safety modules - LED Meaning (Ita, Eng, Fra, Spa, Ted)
Placement of the acces control light curtains in the paletizer plant: